Skip to main content Skip to main navigation menu Skip to site footer
logo
  • Login
  • Register
E-ISSN: 2822-6453
  • Home
  • Current Issue
  • Archives
  • For Authors
    • Author Guidelines
    • Online Submission
    • Reference Style
    • Call for Papers
    • Language Editing
  • For Reviewers
    • Reviewer Guidelines
    • Become a Reviewer
    • Reviewer Resources
  • Ethics and Policies
    • Artificial Intelligence (AI) Policy
    • Authorship and Contributorship
    • Conflicts of Interest
    • Copyright and Permission
    • Corrections and Retractions
    • Crossmark Policy
    • Editorial Policy
    • Human and Animal Rights
    • Informed Consent Policy
    • Journal Management
    • Open Access Statement
    • Publication Ethics Policy
    • Research Ethics Policy
  • Journal Info
    • About the Journal
    • Abstracting & Indexing
    • Editorial Board
    • Peer Review Process
    • Publication Fee
    • Society Information
    • Contact
  1. Home /
  2. Search

Search

Advanced filters
Published After
Published Before

Search Results

##search.searchResults.foundPlural##
  • An overview of intraoral scanners and computer-aided design software programs used in scan design stages in digital dentistry

    In prosthetic dental treatments, obtaining the negative of the prepared area in the most accurate way directly affects the success of the restoration to be made. Therefore, it is necessary to give importance to the impression material and the impression technique used. Impression materials have undergone changes over the years in order to record the most accurate and sensitive detail. Studies have tried to improve many physical and chemical properties of the impression material. Despite this, it should not be forgotten that there are numerous external factors such as the skill of the clinician, environmental conditions, and storage conditions for the impression to be obtained. Developments in computer-aided design and design (CAD/CAM) technology have significantly increased the use of these systems in dentistry in recent years. In dentistry, many companies in the market aim to minimize the problems that may occur in the laboratory and clinical environment by adding intraoral or extraoral scanners to CAD/CAM systems. The first step of dental CAD-CAM systems is digital scanning with an intraoral or laboratory scanner. This step is followed by the construction phase of restorations with digital design and production devices on the computer. Therefore, the success of these restorations depends largely on the accuracy and precision of the scanning devices. This review will discuss CAD/CAM systems and intraoral scanners and software programs.
    Digital dentistry, intraoral scanners, CAD/CAM systems, digital impression, scanning accuracy, digital workflow
    Muhammed Burak Süzen, Hayriye Yasemin Yay Kuşçu
    27.08.2026
    e260828
    Abstract Views: 538 Download: 184 DOI 10.5577/jomdi.e260828
  • Full-arch dental impressions: Conventional, digital, and photogrammetric techniques

    Advances in digital dentistry now permit the fabrication of full-arch prosthetic restorations through a fully digital workflow, extending from impression acquisition to the production of the definitive prosthesis. Intraoral scanning has become an acceptable alternative to conventional impression techniques, providing valuable information for diagnosis, restorative dentistry, orthodontic analysis, and implant-supported prosthodontics. Despite the many advantages offered by digital methods, conventional impression techniques using polyether, polyvinyl siloxane, and vinyl siloxanether materials remain widely used by clinicians because of their excellent dimensional stability and well-documented precision. This review compares and critically discusses conventional and digital impression techniques for acquiring full-arch dental registrations, with particular attention to their accuracy, advantages, limitations, and clinical indications. The accuracy of digital impressions is strongly influenced by inter-implant distance, scan span length, scan body geometry and material, scanner type, operator experience, and intraoral conditions such as mobile mucosa, saliva, and limited anatomical landmarks. For single-unit and short-span restorations of up to four or five units, intraoral scanning achieves accuracy comparable to that of conventional techniques. In long-span and full-arch restorations, however, accuracy tends to decline owing to cumulative image-stitching errors and the scarcity of reference points, a problem that is especially pronounced in completely edentulous arches. Photogrammetry has emerged as a promising alternative for the reliable registration of multiple implant positions, although it inadequately captures peri-implant soft tissues. Overall, technique selection depends primarily on the number of teeth or implants and the distance between them; conventional methods remain preferable for completely edentulous patients, whereas digital workflows are suitable for restorations spanning up to three or four implants. Despite persisting limitations, digital techniques are strong candidates to eventually outperform conventional approaches in dentistry.
    Full-arch impression, conventional impression, digital impression, intraoral scanner, photogrammetry, implant-supported prosthesis, impression accuracy
    Ebru Sümer Ekin
    27.08.2026
    e260826
    Abstract Views: 430 Download: 142 DOI 10.5577/jomdi.e260826
  • Restorative options for primary teeth in pediatric dentistry

    Restoration of primary teeth is a fundamental component of pediatric dental care, as primary dentition plays a critical role in mastication, speech development, esthetics, and the maintenance of arch integrity for the eruption of permanent teeth. Dental caries remains one of the most prevalent chronic diseases in children worldwide, making the selection of appropriate restorative materials essential for achieving durable and biologically acceptable outcomes. This narrative review aims to evaluate the restorative options available for primary teeth in pediatric dentistry, with emphasis on their clinical performance, advantages, and limitations. Due to the anatomical and histological differences between primary and permanent teeth—such as thinner enamel and dentin, larger pulp chambers, and shorter functional lifespan—restorative material selection in primary teeth requires specific considerations. Traditional materials, including dental amalgam, have demonstrated long-term durability and moisture tolerance; however, their use has declined due to esthetic demands and concerns regarding mercury exposure. Glass ionomer cements and their modified forms offer chemical adhesion to tooth structure, fluoride release, and cariostatic properties, making them particularly suitable for children at high caries risk, despite their relatively lower mechanical strength. Resin-based materials, such as composite resins, compomers, giomers, and ormocer-based systems, provide superior esthetics and acceptable mechanical properties, but their clinical success is highly dependent on proper isolation and technique sensitivity. Full-coverage restorations, including stainless steel crowns, veneered crowns, prefabricated zirconia crowns, and newly developed polymer-based crowns, are recommended for extensively damaged primary teeth, especially following pulp therapy. Stainless steel crowns remain the gold standard for posterior primary teeth due to their durability and cost-effectiveness, whereas zirconia and aesthetic crowns offer improved esthetic outcomes with certain limitations related to tooth preparation and retention. Recent advancements in restorative materials and digital technologies, such as CAD–CAM-fabricated crowns, have expanded treatment options in pediatric dentistry. In conclusion, no single restorative material fulfills all clinical requirements. The selection of restorative options for primary teeth should be individualized based on the child’s age, caries risk, tooth location, functional demands, esthetic expectations, and level of cooperation. Appropriate material selection contributes significantly to the long-term oral health and overall well-being of pediatric patients.
    Primary teeth, restorative materials, pediatric dentistry., glass ionomer cements, composite resins, zirconia crowns
    Büşra Karaağaç Eskibağlar, İrem İpek, Özge İlter Er, Buket Ayna
    30.12.2025
    e250070
    Abstract Views: 3509 Download: 1250 DOI 10.5577/jomdi.e250070
  • CAD/CAM technology in dentistry

    The remarkable advancement of dental materials, treatment techniques, and prosthesis manufacturing processes has elevated computer-aided design and manufacturing (CAD/CAM) systems to a new level of clinical capability. Since its introduction to dentistry in the 1980s—beginning with the chairside CEREC system and the Procera framework concept—CAD/CAM has reshaped contemporary practice by enabling aesthetic, durable, and reliably reproducible restorations while transforming the way laboratories design and fabricate both framework (substructure) and monolithic restorations. Because the production stages are tightly controlled and the material blocks are industrially processed, modern CAD/CAM materials also offer improved structural properties—reduced microporosity, greater homogeneity, and lower firing shrinkage—relative to conventionally processed ones, while reducing laboratory steps, working time, and the overall error rate. This narrative review examines the principal CAD/CAM restorative materials, the digital data-processing workflow, and restoration production methods, together with their influence on marginal fit. The main material classes are described—leucite- and lithium-disilicate-reinforced glass ceramics, yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and monolithic zirconia, resin-matrix and nanoceramic blocks, composite blocks, and hybrid ceramics such as Vita Enamic—with their compositions, mechanical properties, indications, and limitations, including flexural strengths ranging from approximately 160 MPa for glass ceramics to substantially higher values for zirconia. The data-processing stage, comprising direct intraoral and indirect model scanning followed by computer-aided design of a virtual model, is reviewed, along with the two production routes: subtractive milling from prefabricated blocks and additive fabrication by selective laser sintering and 3D printing, which minimizes material waste. Marginal adaptation is discussed as a key determinant of restorative success, with reported clinically tolerable misfit values of 50 to 200 µm and CAD/CAM milling shown to provide superior marginal conformance to conventional techniques. Overall, CAD/CAM workflows offer measurable gains in material quality, accuracy, and efficiency over conventional methods, although optimal outcomes depend on correct material selection, appropriate indication, and proper tooth preparation.
    CAD/CAM, dental ceramics, monolithic zirconia, intraoral scanner, marginal adaptation, digital workflow
    Zuhal Görüş, Hayriye Yasemin Yay Kuşçu, Nur Sena Alioğlu Koparal
    29.08.2026
    e260817
    Abstract Views: 373 Download: 127 DOI 10.5577/jomdi.e260817
  • Can digital impression methods eliminate the current problems of conventional impression techniques?

    Conventional impression materials remain a cornerstone of routine dental practice, yet they carry well-documented drawbacks, including a pronounced gag reflex, limited patient comfort, potential soft-tissue trauma, dimensional changes with temperature and elapsed time, the need for disinfection, cross-infection risk, and susceptibility to distortion during transport, storage, and laboratory handling. Digital impression systems have been introduced to overcome these limitations, and their use in dentistry—particularly in prosthodontics—continues to expand. This review compares conventional and digital impression techniques and examines whether digital workflows can resolve the shortcomings inherent to conventional methods. Conventional elastomers such as polyether and addition-type silicones offer excellent dimensional stability and detail reproduction and are currently regarded as the gold standard. Digital impressions, obtained with intraoral or extraoral scanners, provide clear advantages in patient comfort, procedure time, reduced cross-infection risk, elimination of polymerization shrinkage and gypsum expansion, and convenient digital archiving and transfer. However, their accuracy is influenced by scanning area, scanner sensitivity, operator experience, moisture, patient movement, and inter-implant distance. The reviewed literature indicates that intraoral scanners achieve clinically acceptable accuracy for single units and single-quadrant restorations, whereas evidence for full-arch and multiple implant-supported prostheses remains inconsistent, with several studies still favoring conventional impressions. Accuracy—comprising trueness and precision—is especially critical for passive fit in implant-supported restorations. Most comparative data derive from in vitro models that do not reproduce intraoral conditions such as saliva, blood, and patient movement, underscoring the need for further in vivo research. In conclusion, although the benefits of digital impressions are evident, their long-term clinical efficacy and safety require additional investigation, and technique selection should weigh accuracy, time efficiency, learning curve, and cost. A case-specific combination of digital and conventional approaches may offer added benefit.
    Digital impression, intraoral scanner, conventional impression, trueness and precision, prosthodontics
    Yakup Kantaci
    27.08.2026
    e260815
    Abstract Views: 387 Download: 170 DOI 10.5577/jomdi.e260815
  • Comparison of scanning accuracy of different digital intraoral scanners

    Digital intraoral scanners (IOSs) have gained significant importance in modern dentistry by offering accurate, efficient, and patient-friendly alternatives to conventional impression techniques. This review aims to evaluate and compare the image quality and accuracy provided by various intraoral scanners, focusing on the current literature. Factors influencing image quality, such as scanning technology (confocal microscopy, triangulation, active wavefront sampling), operator experience, and scanning strategy, are also discussed. The evaluation includes commonly used IOS devices, including iTero, Trios, Medit i700, and CEREC Primescan, analyzing their performance in clinical and laboratory conditions. The literature suggests that while each scanner has strengths and limitations, all of them provide clinically acceptable results for prosthodontic and orthodontic applications. Furthermore, advancements in software and hardware are continuously enhancing image resolution, data acquisition speed, and ease of use. However, despite the progress, discrepancies in trueness and precision still exist depending on the scanning environment, scan area size, and material reflectivity. This review concludes that selecting an appropriate IOS should be based on clinical needs, operator preferences, and the specific task at hand. Continuous technological development and standardized evaluation methods are essential to further improve IOS reliability and integration into routine clinical practice.
    Accuracy, intraoral scanners, digital scanning, three-dimensional imaging, digital dentistry
    Elif Atasever, Server Mutluay Ünal
    27.08.2026
    e260823
    Abstract Views: 379 Download: 130 DOI 10.5577/jomdi.e260823
  • Current CAD/CAM materials

    Computer-aided design and computer-aided manufacturing (CAD/CAM) technologies have fundamentally reshaped restorative and prosthetic dentistry, streamlining both chairside and laboratory workflows while improving the speed, accuracy, and predictability of treatment. As the range of millable materials continues to expand, evidence-based, indication-specific selection has become increasingly challenging for clinicians and dental technicians alike. This review classifies and critically evaluates contemporary CAD/CAM materials according to their chemical composition—metal, ceramic, composite, polymer, and hybrid—and compares their performance to support rational treatment planning. Drawing on current literature, it surveys a broad spectrum of materials, including metal alloy blocks; feldspathic, leucite-reinforced, and lithium disilicate glass ceramics; glass-infiltrated and polycrystalline oxide ceramics (alumina and yttria-stabilized zirconia); resin nanoceramics; polymer-infiltrated hybrid ceramics; zirconia-reinforced lithium silicate; composite blocks; and polymer blocks such as PEEK and PMMA. For each group, mechanical strength, optical and esthetic properties, biocompatibility, clinical indications, advantages, and limitations are presented within a comparative framework, and the influence of production strategy—chairside versus centralized fabrication and hard versus soft milling—on restoration fit and longevity is discussed. Reported flexural strength ranged from approximately 150 MPa for feldspathic ceramics to well above 1000 MPa for high-strength zirconia, revealing consistent trade-offs between mechanical performance and translucency, most evident as the cubic phase of zirconia increases. Lithium disilicate and zirconia emerged as leading options balancing esthetics and durability, whereas PEEK and composite materials offered advantages in biocompatibility, elasticity, and provisional applications. Overall, no single material is universally optimal; selection should be guided by the specific clinical indication, esthetic demand, and occlusal load, with ongoing advances in digital dentistry expected to further broaden material choice and clinical performance.
    CAD/CAM, block materials, metal alloys, ceramics, polymer blocks, digital dentistry
    Pelin Künarcı, Server MUTLUAY ÜNAL
    29.08.2026
    e260824
    Abstract Views: 708 Download: 291 DOI 10.5577/jomdi.e260824
  • How should I scan for measurement accuracy in full-arch scans?

    The integration of intraoral scanners (IOSs) into routine clinical practice has transformed full-arch digital impression-making, offering improved patient comfort and the potential for high measurement accuracy. However, ensuring reliable trueness and precision across large arch spans remains challenging because of the cumulative errors that arise when extended areas are scanned, which can compromise the fit of prosthetic restorations, generate stress within implant-supported frameworks, and introduce clinically relevant errors in orthodontic planning. This review synthesizes the current evidence on the technical, biological, and operator-related factors that influence full-arch scanning accuracy and outlines clinically applicable strategies to minimize error. The principal challenges discussed include local error accumulation, patient movement, saliva and moisture, soft-tissue mobility in edentulous arches, and operator fatigue, all of which can lead to volumetric deformation of the digital model. Key determinants of accuracy are examined, including scanner technology, scanning path and starting-point selection, operator experience, oral humidity, ambient light, and implant scan-body characteristics. Recommended scanning patterns—linear, zigzag, and segmental approaches—are compared and discussed, together with region-specific strategies for the anterior and posterior segments. The evidence indicates that a disciplined protocol markedly improves trueness and precision: linear progression from the posterior toward the anterior region, segmental scanning in implant-supported cases, regular scanner calibration, a constant scanning speed and distance, effective moisture and ambient-light control, the use of matte scan bodies such as PEEK, and continuous operator training. Future research should prioritize intelligent auto-alignment algorithms, standardized implant scan-body geometries and materials, multicenter evaluation of environmental conditions, and artificial-intelligence-based real-time error detection to further enhance the reliability of digital impressions in clinical practice.
    Full-arch scanning, intraoral scanner, trueness and precision, segmental scanning, digital impression
    Savaş Sağmak, Muhammed Burak Süzen
    27.08.2026
    e260829
    Abstract Views: 342 Download: 131 DOI 10.5577/jomdi.e260829
  • Comparison of cyclic fatigue resistance of different rotational and reciprocal file systems

    Aim: The purpose of this study is to compare the cyclic fatigue resistance of the TruNatomy and ProTaper Next file systems, which work rotational movements, and Reciproc and WaveOne Gold file systems, which work reciprocal movements. Methods: ProTaper Next X2 (25/.06), WaveOne Gold Primary (25/.07), Reciproc R25 (25/.08), and TruNatomy Prime (26/.04) files were used in the cyclic fatigue test. Four groups, 15 files from each group and a total of 60 files, were rotated in an artificial canal made of curved stainless steel with a curvature angle of 60 degrees, an inner diameter of 1.5 mm, and a radius of curvature of 3 mm. The breaking times of the files were determined with a digital stopwatch, and this value was converted into the number of cycles until breaking. Compliance with normal distribution was examined with the Shapiro‒Wilk test. The number of cycles until fracture for the respective files, which did not follow a normal distribution, were compared using the Kruskal‒Wallis test and multiple comparisons were made with the Dunn test. The analysis results were presented as mean ± standard deviation and median (minimum-maximum). The significance level was taken as p <0.050. Results: While the TruNatomy system had the highest number of cycles until fracture occurred, no statistically significant difference was found between the Reciproc and WaveOne Gold systems. The ProTaper Next system showed the lowest cyclic fatigue resistance. Conclusion: Within the limitations of the present in vitro study, TruNatomy, which makes rotational motion, showed the best cyclic fatigue resistance. The ProTaper Next system was the file with the lowest cyclic fatigue resistance. Obtaining similar results for files produced in different shapes and with different movement kinematics allowed us to conclude that cyclic fatigue is multifactorial.   How to cite this article: Akın Tartuk G, Kaya S, Al Tai TN. Comparison of cyclic fatigue resistance of different rotational and reciprocal file systems. J Med Dent Invest 2024;5:e240347. https://doi.org/10.5577/jomdi.e240347
    Cyclic fatigue, endodontic file, ProTaper Next, Reciproc, TruNatomy, WaveOne Gold
    Gizem Akın Tartuk, Sadullah Kaya, Tamara Nabhan Al Tai
    30.12.2024
    e240347
    Abstract Views: 735 Download: 724 DOI 10.5577/jomdi.e240347
  • Effect of different polishing methods applied to denture base materials on microbial adhesion and surface roughness

    Aim: The aim of our study was to investigate the effect of various polishing processes applied to different types of PMMA (polymethyl methacrylate) denture base materials on the surface roughness and microbial adhesion of the base material. Methods: Sixty specimens were prepared from heat-polymerized conventional PMMA (G), injectable PMMA (E), and pre-polymerized CAD-CAM PMMA (C) denture base materials. All the sample surfaces were sanded with silicon carbide abrasives of 800, 1000, 1200, and 2500 grit. The specimens of each denture base material were divided into three subgroups (n=20), in which different polishing methods were applied. The first group was mechanically polished (M), and the other two groups were chemically polished with light-polymerized glaze liquids [Palaseal (Ps), Optiglaze Color (Og)]. A profilometer was used to evaluate the surface roughness. Colony counting was performed to assess bacterial colonization after one day. The data obtained from all these measurements were evaluated using Analysis of Variance and Bonferroni Corrected test was used for multiple comparisons of means ( p = 0.05). The interaction between surface roughness and bacterial colonization was examined using the Pearson’s correlation test. Regression analysis was performed to determine the relationships between them. Results: When PMMA base materials were compared, the lowest average surface roughness (Ra) and bacterial colonization values were obtained in Group C. When the polishing methods were compared, the lowest average surface roughness values were obtained for Group M. As a result of the bacterial colonization measurement, lower colonization values were obtained with standardized mechanical polishing compared to the other groups. Conclusion: There was no difference between the different PMMA base materials in terms of surface roughness; however, there were statistically significant differences in bacterial colonization. Our study showed that mechanical polishing yielded better results than light-activated glazing agents.   How to cite this article: Yarar S, Değer Y, Tekin S. Effect of different polishing methods applied to denture base materials on microbial adhesion and surface roughness. J Med Dent Invest 2023; 4: e230351. https://doi.org/10.5577/jomdi.e230351
    CAD-CAM, digital, PMMA, polishing, surface roughness
    Sadi Yarar, Yalçın Değer, Samet Tekin
    31.12.2023
    e230351
    Abstract Views: 1111 Download: 777 DOI 10.5577/jomdi.e230351
1 - 10 of 10 items

Journal Issue

Vol. 7 No. S1 (2026) Continuous Publication
View Current Issue

Published Volumes

2026
  • Vol. 7 No. S1 (2026): Current Developments in Prosthetic Dentistry
  • Vol. 7 (2026): Journal of Medical and Dental Investigations
2025
  • Vol. 6 No. S1 (2025): Current Developments in Pediatric Dentistry
  • Vol. 6 No. Advanced Online (2025): Journal of Medical and Dental Investigations
  • Vol. 6 (2025): Journal of Medical and Dental Investigations
2024
  • Vol. 5 (2024): Journal of Medical and Dental Investigations
2023
  • Vol. 4 (2023): Journal of Medical and Dental Investigations
2022
  • Vol. 3 (2022): Journal of Medical and Dental Investigations
Show more Show less
2021
  • Vol. 2 (2021): Journal of Medical and Dental Investigations

socialshare

Submit Your Paper
Become a Reviewer

sidebarmenu

Journal Menu

 Home

 Aims & scopes

 Editorial Board

 Author Guidelines

 Abstracting & Indexing

 Peer Review Process

 Ethics Statement

 Plagiarism Policy

 Digital Archiving Policy

 Corrections and Retractions

 Journal History

 Journal Statistics

 Society Information

 Language Editing

 Contact

idr




Citations
Updated daily Google Scholar
All Since 2021
Citations 44 44
h-index 4 4
i10-index 0 0
0 5 10 15 20 25
  • 2 2023
  • 7 2024
  • 21 2025
  • 14 2026
Citations per year
Year Citations
2023 2
2024 7
2025 21
2026 (to date) 14

2026 counts citations recorded so far this year.

ithenticate

Indexed in CiteLink

 

Signatory of DORA

Latest publications

  • Atom logo
  • RSS2 logo
  • RSS1 logo

Information

  • For Readers
  • For Authors
  • For Librarians

Browse

  • Categories
    • DENTISTRY
    • MEDICINE
    • Open Access
    • Original Article
    • Review
    • Case Report
    • Letter to Editor
Most Read Articles
  • Restorative options for primary teeth in pediatric dentistry
    3509 3509 views 2025
  • Use of platelet-rich fibrin (PRF) in the periodontology: A review
    3059 3059 views 2023
  • Endodontic treatment in primary teeth
    2296 2296 views 2025
  • Potential complications and preventive measures in pediatric dental treatments performed under general anesthesia and sedation
    2227 2227 views 2025
  • Does a sloped neck implant design facilitate All-on-4 surgeries? A three-dimensional finite element analysis
    2213 2213 views 2023
Most Cited Articles
  • Use of platelet-rich fibrin (PRF) in the periodontology: A review
    7 7 citations 2023
  • Evaluation of time exposure of different irrigation agents on radicular dentin erosion
    7 7 citations 2022
  • Comparison of second mesiobuccal canal prevalence of maxillary molar teeth by gender and age in a Turkish subpopulation: A cone-beam computed tomography study
    4 4 citations 2021
  • Does a sloped neck implant design facilitate All-on-4 surgeries? A three-dimensional finite element analysis
    4 4 citations 2023
  • Effect of different polishing methods applied to denture base materials on microbial adhesion and surface roughness
    4 4 citations 2023

visitors

Visitors 

Flag Counter

Web Analytics Made Easy - Statcounter

View My Stats

announcement

Announcement

logo
E-ISSN: 2822-6453

Download App

Contact

Publisher: Journal of Medical and Dental Investigations

Email: info@jomdi.org

Website: www.jomdi.org

Address: Publisher ZEUS PUBLISHING www.zeuspublishing.com

Social Media

CiteLinkEBSCOOpen AccessCrossrefGoogle ScholarCOPECreative Commons

Copyright © 2020-2026 | Journal of Medical and Dental Investigations. All rights reserved.
CC BY Open Access articles are distributed under the terms of the Creative Commons Attribution 4.0 International License,
which permits unrestricted use, distribution, and reproduction provided the original work is properly cited.

Privacy notice

This journal stores a session cookie that is required for the site to work, and keeps usage statistics that do not identify you.

More information